Background Malignant tumors routinely present with irregular shapes and complex configurations. The lack of customization to individual tumor shapes and standardization of procedures limits the success and application of thermal ablation. Methods We introduced an automated treatment model consisting of (i) trajectory and ablation profile planning, (ii) ablation probe insertion, (iii) dynamic energy delivery (including robotically driven control of the energy source power and location over time, according to a treatment plan bespoke to the tumor shape), and (iv) quantitative ablation margin verification. We used a microwave ablation system and a liver phantom (acrylamide polymer with a thermochromic ink) to mimic coagulation and measure the ablation volume. We estimated the ablation width as a function of power and velocity following a probabilistic model. Four representative shapes of liver tumors < 5 cm were selected from two publicly available databases. The ablated specimens were cut along the ablation probe axis and photographed. The shape of the ablated volume was extracted using a color-based segmentation method. Results The uncertainty (standard deviation) of the ablation width increased with increasing power by ± 0.03 mm (95% credible interval [0.02, 0.043]) per watt increase in power and by ± 0.85 mm (95% credible interval [0, 2.5]) per mm/s increase in velocity. Continuous ablation along a straight-line trajectory resulted in elongated rotationally symmetric ablation shapes. Simultaneous regulation of the power and/or translation velocity allowed to modulate the ablation width at specific locations. Conclusions This study offers the proof-of-principle of the dynamic energy delivery system using ablation shapes from clinical cases of malignant liver tumors. Relevance statement The proposed automated treatment model could favor the customization and standardization of thermal ablation for complex tumor shapes. Key points • Current thermal ablation systems are limited to ellipsoidal or spherical shapes. • Dynamic energy delivery produces elongated rotationally symmetric ablation shapes with varying widths. • For complex tumor shapes, multiple customized ablation shapes could be combined. Graphical Abstract
Lesion and ablation characteristics per ablated lesion (n = 301).
The quantitative ablation margin (QAM) results for non-subcapsular case
Microwave ablation of hepatocellular carcinoma
Procedural technique including the four phases of SMWA. (A) Planning
Thermal tumor ablation in clinical use. - Abstract - Europe PMC
The Liver Tumor Segmentation Benchmark (LiTS). - Abstract - Europe PMC
Transient changes during microwave ablation simulation : a comparative shape analysis
Thermal ablation with configurable shapes: a comprehensive, automated model for bespoke tumor treatment, European Radiology Experimental
Effect of Non-parallel Applicator Insertion on 2.45 GHz Microwave Ablation Zone Size and Shape
Thermal tumor ablation in clinical use. - Abstract - Europe PMC
Frontiers AC Pulsed Field Ablation Is Feasible and Safe in Atrial and Ventricular Settings: A Proof-of-Concept Chronic Animal Study
Thermal ablation with configurable shapes: a comprehensive, automated model for bespoke tumor treatment
Flow chart illustrating the inclusion process, study cohorts and
Thermal tumor ablation in clinical use. - Abstract - Europe PMC